![](http://www.cas.co.kr/bemarket/imgs/save/upload/img_txt08.gif) |
LS/LSU pan cake load cell, 1tf - 100tf
¢Á FEATURES Hermetically sealed High reliability against fatigue and side force
¢Á ACCESSORY OPTIONS - Accessory for compression - Accessory for tension - Ball type accessory
¢Á Material Paint finished steel
¢Á Cable Braided shield 4-wire round cable with P.V.C-jacket
| |
|
![](http://www.cas.co.kr/bemarket/imgs/save/upload/img_txt09.gif) |
|
Max. capacity |
tf |
1,2,3,5,10,20, 50(LSU),100(LSU),200(LSU) |
Rated output Zero balance |
mV/ V mV/ V |
2.0 ¡¾ 0.005 0 ¡¾ 0.02 |
Accuracy class |
|
A |
B |
Combined error Repeatability Creep for 30min. Temperature effect on Zero Value Output value |
% % %
%/ 10¡É %/ 10¡É
|
0.02 0.01 0.03
0.03 0.03 |
0.05 0.02 0.03
0.03 0.03 |
Excitation Recommended Maximum Resistance Input Output Insulation
|
V V
¥Ø ¥Ø M¥Ø |
10 15
350 ¡¾ 3.5 350 ¡¾ 3.5 £¾2,000 |
Compensated temperature range Operating temperature range |
¡É ¡É |
-10 to +40 -20 to +80 | | |
|
| |
|
|
|
|
|
|
|
|
|
| |